BPM-A204 Anesthesia Machine with Ventilator

Features:

  • The Ventilator adopts microcomputer control with high-definition TFT color LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance;
  • The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation;
  • High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration;
  • Reliable pneumatic transmission system;
  • Economic and proper configuration of technologies, optional as required by the Customer;
  • Modularized design and upgrading. Upgrading is available as required by the Customer.

Specification:

Main body

High-strength engineering plastic rack, light, beautiful and corrosion resistant

Scope of application

adult, child

Gas source

O2, N2O: 0.270.55MPa

Flow meter

O2/N2O: 0.11.0L/min, 1.1~10L/min;

N2O: 0.11.0L/min, 1.1~10L/min.

O2, N2O linkage and N2O Stopper

When using nitrous oxide, oxygen concentration>25%;

When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.

Flow rate of rapid oxygen supply

2575L/min

Low oxygen pressure alarm

There will be sound alarm when the oxygen

pressure < 0.2MPa

Vaporizer

it has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 05 vol%;

Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer;

Vaporizers that are imported with original packaging are also available.

Respiratory circuit 

working mode: all-close, semi-close, semi-open;

releasing pressure: 0.57 kPa

Respiratory bellows

bellows for adults, bellows for children

tidal volume range: 01500 ml

Part of Ventilator

Display mode

High-definitionTFT or color LCD screen display

Ventilation  mode

IPPV,SIPPV,SIMV,PEEP,MANUAL,SIGH(IMV, VCV, PCV)

Ventilation parameters

Tidal volume                    501500ml(20~1500ml)

Rate                                199 bpm

SIMV rate                        2~20bpm

I:E                                   2:11:8 (4:1~1:8)

Inspiratory trigger pressure    -1.02.0 Kpa

PEEP                              02.0 Kpa

Pressure range              1.06.0 Kpa

SIGH           1.5 times the inspiratory time(70-150 adjustable)

Parameters for ventilation monitoring

tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance,flow-volume loop, pressure-volume loop)

Monitoring of oxygen concentration

21%100%

Security Alarm System

1. Oxygen Concentration alarm:

upper limit setting range (21%100%);

low limit setting range  (10%80%).

2. Airway pressure alarm:

upper limit setting range 0.36.0 kPa;

low limit setting range   0.25.0 kPa.

3. Per-minute ventilation volume alarm:

upper limit setting range  3.030L/min;

low limit setting range   1.010L/min. 

4. Sustained high-pressure alarm:it will give alarm when stress have consistently been higher than 2.5 kPa. 

5. Suffocation alarm: it will give sound and light alarm if there is no tidal volume input for 15 seconds.

6. Power alarm.

Power

AC 220V±10%     50Hz±1Hz (UPS, Storage battery)

Mechanical Arms

End-expiratory CO2 monitoring