BPM-FM1203 Fetal Monitor

Features:

light and compact design, simple to use front panel controls
12.1" TFT Colour screen ,folding 90 degree
The system setup can be done very easy and can be stored automatically The internal line 152mm thermal printer can records FHR,TOCO ,The life exceed over 20 years
A standard patient event marker and a clinical event marking button to separately mark Clinical events
Auto Fetal movement are available
Multi-crystals ,wide beam form, high sensitivity ultrasound transducer ,low ultrasound power, Safer to the fetal
AC or Ll-battery operated
More than 12 hours data storage, then can be played and reprinted
Build-in interface to the central nurse station
Technical parameters:

FHR

Transducer: Multi-crystals, wide wave beam, pulsed-wave working method, high sensitivity
Strength: < 5mW/cm2
Working Frequency: 1.0MHz
Signal Processing: Special DSP system and modern recognition
Measurement Range: 50~240bpm
Alarm Range:
       High Limit: 160, 170, 180, 190 bpm
       Low Limit: 90, 100, 110, 120 bpm
Maximum Audio Output Power: 1.5 Watt

TOCO

Measurement Range: 0-100 units
SpO2 Measurement
Measurement Range: 70%~99%
Measure Accuracy: ±3% error
HR Measurement
Measurement Range: 30bpm~240bpm
Measure Accuracy: ±2 bpm

NIBP Measurement

Measurement Range     SYS  6.7~32.0kPa(50~240mmHg)
              MEAN: 3.4~26.6kPa(25~200mmHg)
                      DIA:  2.0~24.0ka(15~180mmHg)
NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of results, taking the bigger one;
HR Measurement Range:40bpm~240bpm
HR Measure Accuracy: ±2 bpm or ±5% of the results, taking the bigger one.
Measure Mode: Manual to start/stop NIBP measurement

Temperature

Arrange:0~50 ºC
Resolution: 0.1 ºC
Accuracy: 0.1 ºC( excluded the error caused by transducer)

Display

LCD shows the FHR trace, TOCO tracd, FM, Doctor Event Mark, Time, Volume etc monitor state, and also it can store and playback.
Dimension: 350L×320W×85H(mm)
Net Weight: 3.5 kg
Environment:
Working Environment: Temperature: +5ºC ~ +40ºC
Atmospheric Pressure: 86kPa ~ 106kPa
Transport and Storage Temperature:
       Humidity: < 93%
       Atmospheric Pressure: 86kPa ~ 106kPa

Transducer Acoustic Output:

Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa.The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal average intensity does not exceed 100 mW/cm2. The sound intensity of this monitor will not exceed 5mW/cm2.

GEL

Viscous aqueous non-sensitizing, hypo-allergenic and non-irritating to skin. Bacteriostat (not sterile)


BPM is the best fetal monitor supplier. Welcome your inquiry.